What the minimum required in order to attach Storwize V7000 LUNs to VIO Server and virtualize them to IBM i?
A. PowerVM Enterprise Edition.
B. AIX/VIOS Host Kit license for the Storage Subsystem and IBM External StorageCompatibility5733-ES1
C. PowerVM Standard Edition.
D. PowerVM Standard Edition and AIX/VIOS Host Kit license for the Storage Subsystem.
正解:C
質問 2:
An operator shut down an operating IBM i partition from the HMC. What is the result of this action?
A. RAID integrity may be compromised.
B. The next IPL of the partition will be an abnormal IPL.
C. Objects in disk IOA write cache will be lost.
D. The next IPL will need to be manual and will require a Reclaim Storage to complete.
正解:B
質問 3:
What type of server and client adapters must be configured on the HMC to support virtualized disk presented from a V7000 SAN to an IBM i client partition?
A. One vSCSI server adapter One vSCSI client adapter
B. One SCSI server adapter One ISCSI client adapter
C. One Fibre Channel server adapter One Fibre Channel client adapter
D. One NPIV server adapter One NPIV client adapter
正解:A
質問 4:
What boot mode is required when installing a hosted AIX or Linux partition?
A. System Management Services (SMS)
B. Open Firmware OK prompt (OPEN_FIRMWARE)
C. Diagnostic with default boot list (DIAG_DEFAULT)
D. Diagnostic with stored boot list (DIAG_STORED)
正解:A
質問 5:
An administrator created a VIO Server partition in the System Planning Tool (SPT) and wants to pair the dual disk controllers for the partition.
What is the correct process?
A. Add the controllers Add the disk Select "Controller Optimization" to manage the pairing
B. Add the first controller Add the disk Add the second controller Pair the disk to the dual controllers
C. Add the controllers Pair the dual controllers Add the disk
D. Add the controllers Add the disk Pair the dual controllers
正解:C
質問 6:
An administrator has an IBM i partition hosted by VIO Server (VIOS), and managed by an HMC.
The administrator has hdisk2 through hdiskl7 assigned to a vSCSI adapter, and wants to map 2 more virtual disk units, but receives an error when trying to map the disks to the vSCSI controller.
What is the cause of the error?
A. The client partition must be powered off to map virtual disks to a vSCSl controller.
B. The disk units are incorrectly formatted for AIX/VIOS.
C. The PowerVM license must be upgraded to Enterprise from Standard.
D. The vSCSI adapter limit has been reached.
正解:D
1226 お客様のコメント






Hatsune -
貴社の問題集を利用してA4040-121を受験し、パスしました。
とてもありがとうございました。