Which level of information does the mpstat command provide when run inside an LPAR?
A. Performance statistics for all logical processors inside the LPAR.
B. The simultaneous multi-threading LPAR profile setting.
C. Overall managed system logical processors utilization.
D. Number of online physical processors in the pool where the LPAR resides.
正解:A
質問 2:
A failed integrated tape drive was physically replaced in a small P0WER7+ server. The administrator attempts to use the device and receives this error message:
AN ERROR OCCURRED WHILE WRITING TO THE STORAGE MEDIA THE DEVICE IS NOT READY FOR OPERATION
Which of the following is the most likely cause?
A. The tape drive needs to be powered on before being used.
B. The media inside the failed tape drive was not removed.
C. The tape device microcode needs to be updated.
D. The drive was replaced but the new device information was not configured
正解:D
質問 3:
Which standard filesystem is temporarily used by the mksysb backup process?
A. /mnt
B. /usr/tmp
C. /var/ras/tmp
D. /tmp
正解:C
質問 4:
A mirrored rootvg internal disk, hdisk1, has failed and must be replaced. The remaining mirrored disk, hdisk0, is intact and functioning normally. What is the correct sequence of actions?
A. unmirrorvg rootvg hdisk1 reducevg roolvg hdisk1 rmdev -I hdisk1 -d physically replace hdisk1 cfgmgr extendvg rootvg hdisk1 mirroivg rootvg Run a bosboot on both disks
B. rmdev-l hdisk1 -d physically replace hdisk1 cfgmgr unmirrorvg rootvg hdisk1 reducevg rootvg hdisk1 extendvg rootvg hdisk1 mirrorvg rootvg Run a bosboot on both disks
C. unmirrorvg rootvg hdisk1 rmdev-I hdisk1 -d physically replace hdisk1 reducevg rootvg hdisk1 cfgmgr extendvg rootvg hdisk1 mirrorvg rootvg Run a bosboot on both disks
D. unmirroivg rootvg hdisk1 reducevg rootvg hdisk1 rmdev -I hdisk1 -d physically replace hdisk1 cfgmgr extendvg rootvg hdisk1 Run a bosboot on both disks mirrorvg rootvg
正解:A
質問 5:
What is the name given to the default paging space partition created during AIX installation?
A. hd1
B. hd7
C. hd5
D. hd6
正解:C
質問 6:
Which technology provides the maximum amount of usable storage and resilience for a system with 6 physical volumes?
A. RAID 5
B. RAID 0
C. RAID 6
D. RAID 1
正解:A
質問 7:
What is a mandatory requirement to allow an AIX 7-based NIM Master to install clients over IPv6?
A. The NIM Master must be installed with the AIX Enterprise Edition license.
B. The NIM Master must be running at least AIX 7.1 TLOO Service Pack3 or later.
C. The NIM Master must have both IPv4 and IPv6 connectivity.
D. The NIM Master must use static IPv6 addresses.
正解:D