Exhibit: During the technical discussion the client has expressed the desire to have a configuration where the virtualized systems are utilized as much as possible but with the capability of running maintenance on one of the five compute nodes and keep all of the VMs running. The exhibit shows four different estimates from the Power Configurator. What input power is required to run the configuration during normal operations?
IBM 000-784 Exam
A. 1964W1964W
B. 1440W
C. 1574W
D. 923W
正解:C
質問 2:
Exhibit: Given the client's need for a low-cost solution, the IBM sales team decided to propose an Express foundation configuration, adding a second IBM Flex System Fabric EN4093R 10Gb Scalable Switch to eliminate the network single point of failure.
IBM 000-784 Exam
Which of the following is a true statement about the added 10Gb Scalable Switch module?
A. The second switch module will come fully cabled and configured just like the first switch module, and the Lab Services team will connect itinto the client network as part of their normal Statement of Work
B. The second switch module will come with a factory-default configuration that is unlike the first switch module, it will not be cabled to anything,and it will be out of scope of the Lab Services normal Statement of Work
C. The second switch module will come fully configured just like the first switch module, but not cabled, and that switch will be out of scope ofthe Lab Services normal Statement of Work
D. The second switch module will come fully cabled and configured just like the first switch module; however, that switch will be out of scope ofthe Lab Services normal Statement of Work
正解:B
質問 3:
A client has a PureFlex system and needs to upgrade their Flex System V7000 Storage Node. Which interface would be used to accomplish this?
A. Chassis Manager
B. BIOS upgrade
C. Flex Node Interface GUI
D. FSM
正解:D
質問 4:
A client wants to use the provisioning features of the FSM to deploy Virtual Machines on their p260 compute nodes. They want to use the Storage Copy Services in the Flex System V7000 Storage Node to achieve this. In this configuration where would the appliance image repository be configured?
A. Virtual I/O Server
B. SmartCloud Entry
C. NIM Server
D. FSM
正解:A
質問 5:
Before capturing a Virtual Appliance into the VMControl Image Repository, which software component must be installed in a VM so the image can be customized during deployment?
A. Virtualization Engine
B. Reconfiguration Engine
C. Activation Engine
D. Installation Engine
正解:C
質問 6:
The client has three independent redundant SAN fabrics: One for development, one for validation and one for production. The client will use a chassis with x240 nodes to connect these SAN fabrics. What is the best solution for the client?
A. Use two CN4058 adapters and two CN4093 switches, each with two FoD enhancements
B. Use one CN4054 adapter, LOM, and four CN4093 switches with FoD enhancements throughout
C. Use two CN4058 adapters and four EN4093 switches, each with one FoD enhancement
D. Use two CN4054 adapters and two EN4093 switches, each with two FoD enhancements
正解:B
質問 7:
The IBM Flex System Interoperability Guide is a handy reference document but its information is only as accurate as of its most recent publication date. Where would the technical expert find the latest complete information on supported FCoE configurations?
A. Reference IBM's ServerProven web page
B. IBM System Storage Interoperation Center (SSIC)
C. IBM Flex System product development
D. The FC-BB-5 standards documentation
正解:B