You want to automate a process on the https://acme-test.uipath.com/work-items web page. On this page, the following table is displayed:
You observe that the selector of the element highlighted in red is:
<html app='chrome.exe' title='ACME System 1 - Work Items' />
<webctrl tag='TABLE' />
<webctrl tag='TD' tableCol='2' tableRow='2' />
What is a valid selector to get the 5-th element in the WIID column?
A. <html app='chrome.exe' title='ACME System 1 - Work Items' />
<webctrl tag='TABLE' />
<webctrl tag='TD' tableCol='5' tableRow='2' />
B. <html app='chrome.exe' title='ACME System 1 - Work Items' />
<webctrl tag='TABLE' />
<webctrl tag='TD' tableCol='2' tableRow='5' />
C. <html app='chrome.exe' title='ACME System 1 - Work Items' />
<webctrl tag='TABLE' />
<webctrl tag='TD' tableCol='2' tableRow='6' />
D. <html app='chrome.exe' title='ACME System 1 - Work Items' />
<webctrl tag='TABLE' />
<webctrl tag='TD' tableCol='6' tableRow='2' />
正解:C
質問 2:
A developer entered custom values in the Browser property in the UI Automation section of the Activity Project Settings menu.
Which set of activities can be affected by this change?
A. Navigate To and Attach Browser
B. Open Browser and Navigate To
C. Open Browser and Close Tab
D. Attach Browser and Open Browser
正解:C
質問 3:
A developer uses Open Browser activity to launch UiPath Docs website. However, as the internet connection is unstable, the developer wraps it in a Retry Scope activity. Please choose the correct statement about this solution.
Please find the properties of Retry Scope activity below
Please find the properties of Open Browser activity below
A. With these settings, the robot will try to execute the Open Browser activity 4 times overall.
B. If the Element Exists activity returns False after all retries, an error will be thrown.
C. Each time the Browser is not opened, an error will be thrown.
D. If the Element Exists activity returns False after all retries, the robot will continue the execution and no error will be thrown.
正解:B
解説: (Pass4Test メンバーにのみ表示されます)
質問 4:
Which file in the Robotic Enterprise (RE) Framework reads the Data/Config.xlsx file and retrieves assets from Orchestrator into the process?
A. InitAllApplications.xaml
B. Process.xaml
C. KillAllProcesses.xaml
D. InitAllSettings.xaml
正解:A
質問 5:
What happens if you try to end the execution of a job by clicking the Kill/Terminate button in Uipath Orchestrator?
Options are :
A. The execution process is killed.
B. The execution is not impacted if no Should Stop activity has been included in the workflow in Studio.
C. The job state is changed to Canceled/Stopped, even if no Should Stop activity was used.
正解:A,C
柴田** -
Pass4Testのこの問題集は読むのもあまり苦がなく、とにかくやる気が起こるテキストです。
教科書がメインになるので、必要に応じて不安な分野は
UiPath-ARDv1問題集に当たっても良いと思います。