You are adding an additional node to a single-node cluster.
Which of the actions should be performed after this upgrade? (Choose two.)
A. Verify that HA is enabled.
B. Verify that epsilon is not assigned.
C. Verify that epsilon is assigned.
D. Verify that HA is disabled.
正解:C,D
質問 2:
Users are experiencing Kerberos authentication problems when attempting to access CIFS shares on the AcmeFS01 SVM. However, users are able to access shares hosted on Windows servers. You verify that network connectivity, between the SVM and the domain controllers, is working correctly.
What should you do to troubleshoot the authentication issue?
A. Verify that the SVM data LIF is on its home port.
B. Ensure that the time on the ONTAP cluster is correct.
C. Verify that the users' computers can resolve DNS hostnames.
D. Verify that the users' computers can ping the SVM data LIF.
正解:C
質問 3:
You are configuring the transport protocol settings and are connecting to storage systems that are running ONTAP.
Which two protocols are supported by SnapDrive for this task? (Choose two.)
A. HTTPS
B. RPC
C. TCP
D. HTTP
正解:A,D
質問 4:
Users are unable to access data stored on an ONTAP cluster. The storage aggregate show command reports that the aggregates are offline and wafl_inconsistent.
Which action would you perform to recover the aggregate?
A. Execute the storage aggregate online command from the cluster shell.
B. Perform an aggregate copy and delete the source aggregate.
C. Execute the aggr online command from maintenance mode.
D. Use file system recovery tools to recover the aggregate.
正解:D
質問 5:
Using QoS statistics for a group of volumes on one node, you notice that most of the latency comes from the data layer.
In this scenario, which statement is correct?
A. There is too much indirect traffic from other nodes.
B. High disk use is increasing CPU usage.
C. The CPU on the node is overused.
D. QoS processing is increasing CPU usage.
正解:B
質問 6:
A customer created a new volume on an SVM for testing. During the first day of testing, the customer copied data to the volume using NFS and consumed 75% of the free space. The second day of testing required the existing data to be deleted and replaced by an equal amount of different data. During the copy, an error message stated that the volume was full.
What would explain the observed error?
A. The user did not have permissions to the export.
B. The old data is still contained within a snapshot.
C. Vscan stopped the write due to an infection.
D. The client lost connectivity to the export.
正解:D