Ralph wants to use IBM Web Experience Factory to quickly make a new portlet based on a REST service call, so that it has an input page, a view page, and a details page. What should be his first step?
A. Put a call to the REST Service Call builder in an existing portlet.
B. Use a different approach. Web Experience Factory does not support REST services.
C. Use File / New / Web Experience Factory Model and select the REST-based View and Form.
D. Create JSP pages for the different pages.
正解:C
質問 2:
Sean wants to trace the value of a variable as a model he is running to help track down a problem somewhere in a computation later in the model. How can he trace the value of the variable?
A. Inspect the logging.properties file for variable values because all changes are reflected in this file at run time.
B. Use the enable Debug Tracing field on the Variable builder.
C. Add a Debug Tracing builder to the model specifying whether to trace all actions or naming a specific action to trace.
D. Add an entry to the log4j.properties file indicating the model and action to trace.
正解:C
質問 3:
Sam is using the CMIS Document Access builder to allow his model to make service calls to FileNet. His FileNet administrator has told him that he can use the basic HTTP Access Scheme, and has provided him a user name and password. How would he set this up?
A. Create a java class that implements com.bowstreet.builders.webapp.cmis.CmisHttpConnection with class name BasicHttpConnection.
B. Select Basic Authentication for the Runtime Authentication input and specify username and password in /WEB-INF/config/cmis_config/designer/defaultCredentials.properties.
C. Select Basic Authentication for the Runtime Authentication input and enter username in Runtime User name and password in Runtime password.
D. Select Basic Authentication for the Runtime Authentication input and enter username and password as the JVM properties CMISUserName and CMISPassword in IBM WebSphere Application Server administration.
正解:C
質問 4:
Robin has network access to her IBM WebSphere Portal server, and has deployed a project to it. How does she update the project on the WebSphere Portal server?
A. Regenerate the WAR file and re-save the configuration of the portlet on the server
B. Regenerate the WAR file and invoke the proper xmlaccess script
C. Regenerate the WAR file, its changes will automatically deploy
D. Save and run any model in the project, this will automatically re-deploy
正解:C
質問 5:
Tom has installed IBM WebSphere Portal to use as his development server. He would like to publish an existing project to the new server to test his portlets. What type of Server Configuration should he select for his server?
A. IBM WebSphere Portal Server
B. IBM WebSphere Application Server
C. IBM WebSphere Application Server and IBM WebSphere Portal Server
D. Pick the first one in the list and the software automatically determines the correct server type.
正解:C
質問 6:
Paul has an existing Service Provider model and now needs to add a Transform Filter builder to allow specific content to be filtered out of the data. After adding the Transform Filter builder, how does Paul get the filtered results to be used by the existing Service Operation builder?
A. Use the override results in the Service Definition builder to point to the filtered data service output.
B. The filtered results are automatically used by the existing Service Operation builder in the provider model.
C. Change the input "Action to Call" to point to the Transform Filter data service in the Service Operation builder.
D. Write an Action List to map the data from the original service operation.
正解:C
質問 7:
Sally has created a simple Hello World model and wants to edit one of the builder calls. How does she begin editing?
A. Locate the builder call in the Navigator, then use Open With to edit in a text editor.
B. Double-click the builder call or right-click and Open, then edit in the Builder Call editor.
C. Right-click the builder call and select Edit.
D. Copy the builder call and edit from the copy, then re-import the builder into the model.
正解:B
質問 8:
An event can be defined for the Client Event Handler builder with which other builder?
A. Dojo Form Dialog
B. Submit Form Event
C. Client Side Event Declaration
D. Event Declaration
正解:D
質問 9:
Which of the following best describes the Discardable Variable builder?
A. The Discardable Variable builder has been deprecated and should no longer be used.
B. This builder can be used to mark a variable created by other builders as discardable so that its
value is not stored past the end of the request,
unless developers specify that it should be cached and for how long to cache it.
C. This builder stores all variable data in browser cookies, with a specified expiration time after
which the browser discards the values.
D. This builder removes all unused variables from the web application to minimize the size of the
application. The variables no longer show up in the Web Application Design view in IBM Web Experience Factory Designer after applying this builder.
正解:B