After expanding a two-node AFF A300 cluster with two AFF A700 nodes, you observe latencies when data is accessed indirectly. The system node run -node -command netstat command shows retransmits and packet drops on the LIFs. The AFF A700 nodes with 40 Gbps and the AFF A300 connect with 10 Gbps to the cluster interconnect. You are using Cisco Nexus 3132Q cluster interconnect switches. You just updated to ONTAP 9.8 software.
In this scenario, what is causing this problem?
A. The 10 Gbps to 10 Gbps cluster Interconnect is creating a speed mismatch.
B. The AFF A300 Is using an adapter card for the cluster Interconnect, but only onboard ports are supported.
C. There is an NXOS firmware mismatch, verify in the Interoperability Matrix (1MTJ for a supported version.
D. AFF A300 and AFF A700 node mixing Is not supported in ONTAP 9.8 software.
正解:A
解説: (Pass4Test メンバーにのみ表示されます)
質問 2:
Your customer complains about missing volume snapshot copies on a SnapMlrror destination. While investigating this case, you notice an executed SnapMirror resync operation in the event logs of the system.
In this scenario, what Is the cause of this problem?
A. The autodelete option removed Snapshot copies before the resync.
B. NetApp ON TAP System Manager removed these snapshot copies due to a snapshot schedule.
C. Newer Snapshot copies than the common snapshot that was chosen for resync were removed automatically at the destination.
D. Snapshot copies were manually removed from the destination after the resync.
正解:C
解説: (Pass4Test メンバーにのみ表示されます)
質問 3:
Your customer noticed in NetApp Active IQ that their NetApp Cloud Volumes ONTAP for Azure HA solution is no longer sending AutoSupport messages over HTTPS. A support ticket has been opened to find out why. No changes have been made to the Cloud Volumes ONTAP for Azure HA environment.
In this scenario, which two autosupport command parameters should be used to validate that AutoSupport Is working properly? {Choose two.)
A. -proxy-url
B. -to
C. -transport
D. -mail-hosts
正解:A,C
解説: (Pass4Test メンバーにのみ表示されます)
質問 4:
An administrator receives the following error message:

What are two causes for this error? (Choose two.)
A. There Is excessive SSD load causing the wear leveling to become unbalanced.
B. An SSD disk is performing garbage collection to create a dense data layout.
C. There is excessive SATA HDD load.
D. A disk is falling.
正解:A,B
解説: (Pass4Test メンバーにのみ表示されます)
質問 5:
After a motherboard replacement on a NetApp AFF A300 in a SAN environment, the customer states that ports 0e and 0f are unable to connect to the fabric. The ports report "offline".
What would you examine first to troubleshoot the issue?
A. vserver fcp wwpn-alias show command output
B. system node hardware unified-connect show command output
C. vserver fcp interface show command output
D. storage port show command output
正解:B
解説: (Pass4Test メンバーにのみ表示されます)