Click the exhibit button.


Many end users are complaining that logging in their systems takes a long time. When the login to the desktop finishes, everything is fine. The home directories are on NetApp storage. You do not see any significant disk or CPU contention on the controller, so you gather output statistics from the controller and focus on SMB.
Referring to the exhibit, which two actions would help diagnose the problem? (Choose two.)
A. Engage your Windows team to make sure that the domain controllers are not overloaded.
B. Engage your desktop team to collect network traces from the clients.
C. Collect more statistics to determine whether the controller itself is causing latency.
D. Engage your network team to make sure that there are no issues between the storage controller and the domain controller.
正解:C,D
質問 2:
Click the exhibit button.

Your customer added a new DS4246 shelf to their FAS system. They created an aggregate on the new shelf.
Two weeks later, they log in to Active IQ and discover the Medium Impact error shown below.
"Both SAS connections from one controller go to the same shelf."
Referring to the exhibit, which statement is correct?
A. A faulty cable is causing the problem.
B. You can correct this problem without downtime on the FAS system.
C. You are unable to obtain a "Cable Visualization" overview from Active IQ.
D. A faulty IOM is causing the problem.
正解:B
質問 3:
Which statement is correct about the wafliron command?
A. The wafliron command is used to correct WAFL i2p inconsistencies.
B. The wafliron command is used to correct inconsistent WAFL metadata.
C. The wafliron command is used to correct parity inconsistencies.
D. The wafliron command is used to correct inconsistent user data blocks.
正解:B
質問 4:
Click the exhibit button.

A customer's system reported several errors. There was no disruption, but the customer is concerned about the system's health.
Referring to the exhibit, which statement is true?
A. Storage redundancy is degraded.
B. One of the IOM modules on shelf 20 has failed.
C. One of the switches has failed.
D. Port 1D on the system has failed.
正解:A
質問 5:
After you replaced the motherboard, the node stopped in the "waiting for the cluster application to come online" state.
Which two actions should you perform to troubleshoot this problem? (Choose two.)
A. Verify the setting of the cluster interconnect switch.
B. Check the status of the cluster with the cluster ring show command.
C. Verify that the physical links on the cluster ports are up.
D. Check the status of the HA with the interconnect-up field of storage failover show command.
正解:B,D
質問 6:
Click the exhibit button.

You are investigating an AutoSupport Disk Redundancy Failed alert. Cluster A lost connectivity to storage bridge BrB1, while cluster B lost connectivity to storage bridge BrA1.
Referring to the exhibit, which three components need investigation? (Choose three.)
A. FC switch SwA1
B. FC switch SwA2
C. ISL cables
D. storage bridges BrB1
E. FC switch SwB1
正解:A,C,E
質問 7:
You configured iSCSI multipathing on a Windows host to a 2-node ONTAP cluster so that you can attach to some LUNs. You see that the host logging in to both iSCSI LIFs in the ONTAP cluster, and you notice that the igroup is correctly set. After you open Disk Management and rescan for disks, the NetApp LUNs do not show up.
In this scenario, what should be performed to enable the LUNs to be visible to the Windows host?
A. Set up Selective LUN Mapping (SLM) and try scanning again.
B. Set up LUN mapping and try scanning again.
C. Configure the ONTAP nodes for HA and try scanning again.
D. Configure the SVM for FCP and try scanning again.
正解:A
井*望 -
一問一問実際に手を動かして書いてみる練習で合格を手にしました。Pass4Testの問題集はいつも素敵でございますね。