Click the Exhibit button.
You have a 2-node data ONTAP 8.3 cluster.
Based on the exhibit, which change must be made to make svm1 conform to iSCSI best practices?
cl01::> net int show -vserver
svm1 -data -protocol iscsi
Logical Status Network
Current Current Is
Vserver Interface Admin/Oper
Address/Mask Node Port Home
----------- ---------- ------
---- ------------------ -----
-------- ------- ----
svm1
up/up 10.204.34.25/24 cl01-01
a0a 434 true
cl01::>iscsi show -vserver
svm1
Vserver: svm1
Target Name: iqn.1992 -
08.com.netapp: sn.ca5eaa069c211
Target Alias: svm1
Administrative Status: up
A. An iSCSI LIF must be added to node cl01-02.
B. The Target Alias must be modified to match the Target Name.
C. The iSCSI LIFs must be moved to a physical interface; iSCSI LIFs are not supported on top of an ifgrp.
D. The iSCSI LIFs must be moved to a VLAN higher than 1024.
正解:B
質問 2:
Which two port personality combinations are valid for the onboard UTA2 ports on a FAS8040 controller?
A. e0e/0e - fc
e0f/0f - fc
e0g/0g - fc
e0h/0h -cna
B. e0e/0e - cna
e0f/0f -cna
e0g/0g - fc
e0h/0h - fc
C. e0e/0e - fc
e0f/0f - cna
e0g/0g - fc
e0h/0h -cna
D. e0e/0e - fc
e0f/0f - fc
e0g/0g - cna
e0h/0h -cna
正解:A
質問 3:
A Windows 2012 Server has a 1 GB thin-provisioned LUN in a 10 GB thin-provisioned volume. After copying a 500 MB
file to the LUN, you observe the LUN using 500 MB of space in the volume. After deleting the 500 MB file, you observe
the LUN is still using 500 MB of space in the volume.
Which two steps are required to reclaim the space? (Choose two.)
A. Run TRIM on the host.
B. Empty the Recycle Bin on the host.
C. Press Optimize in the Windows Defragment and Optimize Drives utility.
D. Enable space-allocation on the LUN.
正解:A,D
質問 4:
You have an iSCSI host that is unable to connect to an SVM named svm1 over a LIF name lif1. The home node and port
of lif1 is port e0e. The event log show command displays the error ISCSI:
network interface disabled for use; incoming connection discarded.
Which command would you use to resolve the problem?
A. network interface modify -vserver svm1 -lif lif1 -failover-group Default
B. broadcast-domain add-ports -broadcast-domain iscsi -ports cI01-01:e0e
C. iscsi interface enable -vserver svm1 -lif lif1
D. vserver iscsi create -target-alias svm1 -status-admin up -vserver svm1
正解:C
質問 5:
You currently have the following configuration on your cluster:
cl01::>igroup show -instance
Vserver Name: svm1
Igroup Name: ig2
Protocol: mixed
OS Type: linux
Portset Binding Igroup: -
Igroup UUID: 3fb136c7-cfd6-11df-a9ab-123478563412
Initiators: -
What must you do to limit the LIFs that are used by an initiator to access a LUN?
A. Create a portset.
B. Create an additional igroup.
C. Change the OS type to windows_gpt.
D. Change the protocol to iSCSI.
正解:A
解説: (Pass4Test メンバーにのみ表示されます)
質問 6:
You created a 5 TB VMware volume "vol_esx_nfs1" in "svm1" for an NFS datastore. The storage efficiency savings of
the vmdks are one over 50%, but the application team wants to minimize the possibility of an out-of-space condition.
You enable autogrow, autoshrink, and snapshot autodelete with the following commands:
volume modify -vserver vm1 -volume vol_esx_nfs1 -space-mgt-try-first volume_grow
snapshotautodelete modify -vserver vm1 -volume vol_esx_nfs1 -enabled true -delete-
orderoldest_first -target-free-space 10% -trigger volume
volautosize -vserver vm1 -volume vol_esx_nfs1 -mode grow_shrink -maximum-size 10 TB -
minimum-size 5 TB -grow-threshold-percent 80 -shrink-threshold-percent 60
What will these commands do?
A. Grow the volume before deleting the Snapshot copies.
B. Delete the oldest Snapshot copies before growing the volume.
C. Shrink the volume before deleting the Snapshot copies.
D. Increase the Snapshot copy reserve before growing the volume.
正解:D
質問 7:
Which protocol allows to access a controller's CLI interface?
A. NTP
B. IMAP
C. SSH
D. TFTP
正解:C
解説: (Pass4Test メンバーにのみ表示されます)
質問 8:
A customer is configuring their host for FC connectivity to a clustered Data ONTAP storage solution. They have
installed a 4 GB FC HBA into the host and connected it with optical cables to an 8 GB FC switch. They have also
connected the UTA2 ports from the FAS2552 with 16 GB SFP+ optics installed using optical cables to the switch.
Which two actions will improve host FCP throughput? (Choose two.)
A. replacing the existing 8 GB FC switch with a new 16 GB FC switch.
B. adding 16 GB FC HBA and appropriate optics
C. replacing the optical cables with copper TwinAx cables.
D. replacing the switch with a 10 GB Ethernet switch
正解:B,D
藤井** -
万全を期すのなら。
力作だと思いますので、使い込みたいと思います。自分でペースを考えて勉強した方が効率的。