You have a Windows 2003 host using the NetApp ONTAP DSM MPIO environment with a FAS6000 high availability configuration running single image cfmode.
When you disconnect a cable from the FC switch to a storage target port, how will the I/O fail over?
A. I/O will fail over to any port on the original controller but NOT on the partner controller that is part of the associated portset. Choice of path will be controlled by the host's MPIO weighting table.
B. I/O will fail over to any port on either controller that is part of the associated portset. Choice of path will be controlled by NetApp storage system igroup settings.
C. I/O will fail over to any port on the original controller that is part of the associated portset. Choice of path will be controlled by NetApp storage system igroup settings.
D. I/O will fail over to any port on either controller that is part of the associated portset. Choice of path will be controlled by the host's MPIO weighting table.
正解:D
質問 2:
Click the Exhibit button.

When should you define the space management policy that is shown in the table?
A. when you want to thin provision the LUNs and make the volume size less than the LUN size
B. when you want to set aside overwrite reserve space for the LUNs so that writes never fail with the presence of Snapshots
C. when you want to guarantee space for Snapshots by letting the volume autogrow
D. when you want Data ONTAP to start deleting Snapshots to recover space from the volume before growing the volume
正解:A
質問 3:
When assessing a current storage solution, it is critical to document the current NetApp storage system configuration.
Which factor should NOT be considered when documenting this existing configuration?
A. storage system name and IP
B. host power cables and power usage
C. current data layout (RAID groups, aggregates, volumes, etc...)
D. Data ONTAP version
正解:B
質問 4:
Which three tasks should be completed as part of the site preparation for install? (Choose three.)
A. verify power drops in the equipment location
B. verify equipment move path
C. determine aggregate layout
D. make contact with data center personnel
E. plan zoning configuration
正解:A,B,D
質問 5:
Which command on a NetApp storage controller will display the average service time on a FC target port basis every five seconds?
A. sysstat -i 5
B. lun stats -i 5
C. sysstat -f 5
D. fcp stats -i 5
正解:D
質問 6:
What is the appropriate method for testing high availability controller failover?
A. issue the takeover command from a controller
B. issue the giveback command from a controller
C. shut down a controller
D. pull a power cord from a power supply on a controller
正解:A