You are attempting to establish a cluster peer relationship between two NetApp clusters, but the peering process fails.
What is a cause for this failure?
A. The cluster management LIF for the cluster cannot communicate with the cluster management LIF for the peer cluster.
B. The node management LIF on each node cannot communicate with the node management LIF on each node in the peer cluster.
C. The cluster LIFs on each node cannot communicate with the cluster LIFs on each node in the peer cluster.
D. The intercluster LIF on each node cannot communicate with the intercluster LIF on each node in the peer cluster.
正解:D
質問 2:
Click the Exhibit button.

An administrator built a FlexPod solution using VMware vSphere 6.0.
The ESXi hosts are using NFS for storage connectivity.
NFS is configured on the ESXi hosts and the NetApp storage virtual machine (SVM).
NFS LIFs are reachable using the ping command form the ESXi hosts.
The administrator creates a volume called "datastore_nfs_0" on the SVM to use for the NFS datastore.
When the administrator attempts to connect to the NFS datastore from the vSphere client, the task fails with the error shown in the exhibit.
What should the administrator do to ensure that the NFS datastore will be created?
A. Verify that the export policy contains the ESXi hosts.
B. Verify that the number of connected NFS mounts is less than 255 on the ESXi hosts.
C. Verify that the default security style of the "datastore_nfs_0" volume is set to UNIX.
D. Execute the vmkping command to verify jumbo frames are working end to end.
正解:A
質問 3:
An administrator has a FlexPod solution with VMware vSphere. The administrator is migrating all network traffic from standard switches to vSphere distributed switches. Virtual machines (VMs) are currently using VM port groups called VLAN_500 and VLAN_501 on standard virtual switch vSwitch3. A new distributed switch called dvSwitch_VM is created and new distributed port groups are configured for each VM traffic VLAN. VMs are configured to use the new port groups. After the change, VMs on VLAN 501 report a loss of network connectivity; however, VMs on VLAN 500 are not showing any connectivity issues.
The symptoms are experienced for VMs on all ESXi hosts.
Which action must the administrator perform to solve the problem?
A. Reboot the virtual machines to re-establish network connectivity.
B. Configure the dvSwitch_VM port binding to Ephemeral.
C. Create a new vmkernel port on dvSwitch_VM for VLAN 501.
D. Add the correct VLAN ID to the new distributed port group for VLAN 501.
正解:B
質問 4:
You are asked to increase read performance for a single aggregate; however, there are no
PCI-e slots available in the NetApp cluster nodes.
In this scenario, which feature meets these requirements?
A. Advanced Drive Partitioning
B. Thin Provisioning
C. Flash Cache
D. Flash pool
正解:D
質問 5:
You want to run the FlexPod execution profile in NetApp Config Advisor.
Which three login credentials are required to perform this task? (Choose three.)
A. UCS Manager
B. NetApp support login
C. ESXi server
D. NetApp cluster
E. Nexus switches
正解:A,B,D
質問 6:
You run NetApp Config Advisor against you FAS8060A storage system. The report states that the flow control settings for ports e0a on each node are incorrect.
Which set of commands will correct this problem?
A. network interface modify- node netapp-01 port e0a-flowcontrol-admin fullnetwork interface modify- node netapp-02 port e0a-flowcontrol-admin full
B. network interface modify- node netapp-01 -port e0a -flowcontrol -admin nonenetwork interface modify -node netapp-02 -port e0a -flowcontrol - admin none
C. network port modify- node netapp-01 port e0a-flowcontrol-admin nonenetwork port modify- node netapp-02 port e0a-flowcontrol-admin none
D. network port modify- node netapp-01 port e0a-flowcontrol-admin fullnetwork port modify- node netapp-02 port e0a-flowcontrol-admin full
正解:C
Hirata -
こちらのNS0-171テキストは更にもう一歩踏み込んで勉強したい方向けのように思います。ありがとうございます。