A network router node using ICMP polling has a green status icon and shows basic information (i.e., status) but is not showing more detailed statistics. What might resolve this issue?
A. Switch polling to SNMP to gather additional polling statistics.
B. Run ping tests to verily communication.
C. Edit the node properties to verily proper polling credentials.
D. Unmanage and re-manage the node.
正解:A
質問 2:
It is noted in flow source view that some devices are showing "never received" in the last received flow column. It is verified that the flows are not being blocked by a firewall. What is the likely cause?
A. node is no longer monitored by the monitoring features
B. flows are IPv6 and not supported by the network monitoring features
C. a primary field of data is missing and being dropped
D. interface is no longer monitored by the network monitoring features
正解:C
質問 3:
The unclassified traffic in the web console has been identified as MSSQL traffic. It is known as an application mapping that hybrid cloud observability maps by default. Which two of the following reasons explain why the traffic is showing as unclassified? (Choose two.)
A. A different port is being used.
B. A firewall is blocking the traffic.
C. The source or the destination port field is not present.
D. The version of MSSQL being used is not supported.
正解:A,C
質問 4:
A problem occurred on the main polling engine and the server fails. It is noted that statistics for the networking devices polled by a universal device poller (UDP) custom monitor are missing. Which two of the following reasons are possible causes of this event? (Choose two.)
A. networking devices are not assigned to the UDP
B. UDPs are tied to the polling engine on which they are hosted
C. data collection for any UDPs stops on the server
D. UDPs do not collect data from failover or hot standby engines
正解:B,C
質問 5:
Which three of the following flow protocols does hybrid cloud observability support? (Choose three.)
A. NetFlowv6
B. J-Flow
C. NetFlowv9
D. sFlow
正解:B,C,D
質問 6:
An unknown traffic event is noted in the web console. What is the likely cause?
A. a firewall is blocking the traffic flow configurations
B. incorrectly configured source or destination port in the flows
C. receiving flows from a device not monitored by the network
D. missing a byte group from flow field configurations
正解:C