As part of the VMware Cloud Foundation (VCF) logical design, the architect documented the following requirement:
The solution must be able to support latency-sensitive workloads.
Which two physical design decisions will meet this performance requirement in the workload domain? (Choose two.)
A. Advanced Memory Tiering with NVMe: Enabled
B. Intel TDX and AMD's SEV-SNP integration
C. vSAN Deep Snapshots: Enabled
D. vSAN Global Deduplication: Enabled
E. NSX Enhanced Data Path: Enabled
正解:A,E
解説: (Pass4Test メンバーにのみ表示されます)
質問 2:
An architect is designing a new VMware Cloud Foundation (VCF) solution. They are meeting with the key stakeholders and subject matter experts (SMEs) for the first time as part of the requirements gathering process. The following information has been shared with the architect prior to the meeting:
- Names and job titles of the attendees
- Project timelines and budget
What step should the architect perform as part of this initial requirements gathering workshop?
A. Ask questions to agree on the key product features the SMEs want from the design.
B. Ask questions to start a discussion on the business objectives and desired outcomes.
C. Open the meeting with a list of the VCF design decisions from the public documentation to agree on any required changes.
D. Open the meeting with a diagram of the VCF topology that must meet the customer requirements in order to start a discussion.
正解:B
解説: (Pass4Test メンバーにのみ表示されます)
質問 3:
An architect is responsible for designing a new VMware Cloud Foundation (VCF)-based Private Cloud solution. During the requirements gathering workshop with key customer stakeholders, the following information was captured:
- The solution must support running 50,000 workloads concurrently
across all sites.
- The solution must support the concurrent deployment of up to 10
workloads.
When creating the design document, which design quality should be used to classify the stated requirements?
A. Recoverability
B. Performance
C. Availability
D. Manageability
正解:B
解説: (Pass4Test メンバーにのみ表示されます)
質問 4:
As part of the VMware Cloud Foundation (VCF) logical design, the architect documented the following requirement:
- The solution must include high security hardening levels to meet
military compliance standards.
Which two physical design decisions will meet this security requirement in the workload domain?
(Choose two.)
A. The advanced setting UserVars.SuppressShellWarning will be configured to 0 across all ESXi hosts in a VI workload domain cluster.
B. NTP will be configured to the internal NTP servers of 192.168.12.1 and 192.168.24.1.
C. The certificate of the VI workload domain vCenter Server will be issued by RootCA.Military.Domain.com.
D. The vSAN storage policy will be configured as Secondary Failures to Tolerate = 1.
E. VCF Operations will be configured to renew the SSL certificate for vCenter Server per security policies.
正解:B,C
質問 5:
An architect is working on a VMware Cloud Foundation (VCF) architecture design and identified the following requirements:
- The organization is using a third-party virtual appliance that does
not support overlay networks.
- The virtual appliance must reside on the same L2 domain as an
external physical firewall.
- The virtual appliance also needs access to workloads that are
currently hosted on overlay segments provided by NSX.
Which design decision should the architect make to meet these requirements?
A. Connect the virtual appliance to a VLAN-backed segment and configure NSX bridging to allow access to overlay segments.
B. Place the virtual appliance and all workloads on VLAN-backed segments.
C. Request the third-party vendor to certify the virtual appliance for NSX Overlay segments.
D. Connect the virtual appliance to an overlay-backed segment and use static routes to the firewall.
正解:A
解説: (Pass4Test メンバーにのみ表示されます)
質問 6:
VMware Kubernetes Service (VKS) cluster exposes three layers of controllers to manage its lifecycle. Which set correctly identifies these layers?
A. Virtual Machine Service, Cluster API, and Cloud Provider Plugin.
B. Virtual Machine Service, vCenter Appliance, Supervisor Service.
C. API Gateway, StatefulSet Controller, Ingress Controller.
D. Cluster API, Node Problem Detector, CNI Plugin.
正解:A
解説: (Pass4Test メンバーにのみ表示されます)
質問 7:
A design constraint states: "The customer's existing hardware does not support NVMe and cannot be replaced within the project budget." What is the direct implication of this constraint on the vSAN architecture decision?
A. The environment must use vSAN ESA exclusively.
B. The customer must abandon vSAN and use traditional SAN storage.
C. The constraint has no impact on vSAN architecture choice.
D. The environment must use vSAN OSA (Original Storage Architecture), since ESA requires NVMe- based ReadyNodes.
正解:D
解説: (Pass4Test メンバーにのみ表示されます)
質問 8:
An architect is responsible for the design of a VMware Cloud Foundation (VCF) Fleet and the following risk has been identified:
RISK001: There is a risk that frequent infrastructure design changes
may break Disaster Recovery (DR) plans and Service Level Objectives.
What should the architect suggest to mitigate this risk?
A. Setup monitoring & alerting against defined infrastructure service level objectives.
B. Develop a process to review and update DR plans between changes and schedule monthly end- to-end DR tests.
C. Limit infrastructure design change frequency to a maximum of once a month.
D. Configure VM replication with recovery point objective of 5 minutes or less for all workloads from the primary to DR site.
正解:B
解説: (Pass4Test メンバーにのみ表示されます)
質問 9:
An alert in SDDC Manager indicates that the health status of the vSAN cluster is degraded.
Which tool within VMware Cloud Foundation should be used to gather detailed logs and perform in-depth troubleshooting for the vSAN issues?
A. Aria Operations for Logs
B. vCenter Server
C. SDDC Manager
D. Aria Operations for Networks
正解:A
解説: (Pass4Test メンバーにのみ表示されます)
718 お客様のコメント





Esumi -
私が一番おすすめする問題集になりました。2V0-13.25問題集にある問題がたくさん出てきました。ここで報告と感謝差し上げます。