A customer's application runs slowly on their HDFS cluster. The customer is only using a small subset of the data on the cluster.
What is causing the issue?
A. Data Efficiency
B. Data Consistency
C. Data Availability ***
D. Data Locality
正解:C
質問 2:
A customer asks an architect to help troubleshoot low throughput in their high-performance compute (HPC) environment. All 70 HPC nodes have a single 10Gb connection to a 96 port 10Gb switch. The FlashBlade is connected to their dedicated HPC switch with 8x10Gb connections. The HPC application is using a single shared S3 bucket for the data being processed.
Which change is needed to increase throughput?
A. Add more uplinks to the HPC switch. ***
B. Add more IPs to the existing VLAN
C. Add more nodes to the HPC cluster
D. Add more VLANS to FlashBlade.
正解:A
質問 3:
The customer provides the network diagram shown. The customer wants to use RBAC and SMB on the FlashBlade. The customer does NOT use encryption for identity-related traffic.
Which ports must be opened for this to work?
A. Ports 53 and 2049 on Firewalls A and B
Ports 53 and 389 on Firewall C
B. Ports 123, 445, and 636 on Firewalls A and B
Port 445 on Firewall B
C. Port 123 on Firewalls A and C
Ports 445 and 636 on Firewall B
D. Ports 53, 389, and 445 on Firewalls A and C
Ports 53 and 445 on Firewall B ***
正解:D
質問 4:
The customer is deploying FlashBlade on a ship with no immediate access to replacement part inventory. The customer needs at least 100TB of usable capacity at any time. The customer assumes worst case scenario in which FlashBlade can lose two blades between visting the next port where replacement can be shipped.
What is the recommend FlashBlade configuration?
A. 11 blades
B. 10 blades
C. 12 blades ***
D. 13 blades
正解:C
質問 5:
A customer wants to use and orchestration tool to manage the FlashBlade.
How should the customer create the API key?
A. Run 'pureconfig' from the command line
B. Run 'pureadmin' from the command line ***
C. Go to Settings/Users
D. Go to Storage/File Systems/Details
正解:B
質問 6:
A customer has two workflows. One workflow can use either SMB 3.0 or ISCSI. The other only leverage NFS.
What should the architect recommend as a strategy?
A. Use FlashBlade for both environments
B. Use block storage for both environments
C. Use block storage for NFS and FlashBlade for ISCSI
D. Use block storage for ISCSI and FlashBlade for NFS. ***
正解:D
質問 7:
The customer reports that the end clients shown in the diagram are NOT completing jobs on time. Each client writes 300MB/s to the FlashBlade for 45 minutes every hour, and they run concurrently. What does the architect need to do?
A. Increase the number of DataVIPs available to the clients.
B. Stagger the job start times between the clients. ***
C. Increase bandwidth between Switch A and the Router.
D. Add additional mount point on each client.
正解:B
質問 8:
How many rack units (Rus) of space are required to support a multi-chassis FlashBlade with 40 blades?
A. 14 Rus ***
B. 12 Rus
C. 9 Rus
D. 18 Rus
正解:A
有沢** -
今時のアプリを利用した過去問演習にも対応。これで十分だとは思います