A customer with a POWER6 520 running V5R4M5 is considering migrating to a POWER7+ 720. Which upgrade or migration method will work?
A. Upgrade the current machine to IBM i 6.1.0
Perform a full system save on the current machine and full system restore on the new machine.
B. Install 5722-SS1 Native Support Feature (EB34) on the current machine
C. Upgrade the current machine to IBM i 7.1 with Technology Refresh 6
Perform a full system save on the current machine and full system restore on the new machine.
D. Load the 7.1 LIC and OS on the new machine
Perform a GO SAVE 21 on the current machine, and a GO RESTORE 21 on the POWER7+ 720.
正解:C
質問 2:
A customer currently performs all their backups to physical tape. The customer would like to improve the performance of their saves, but does not have the time to perform any major changes to their backup strategy or system design.
Which product will allow them to potentially decrease their backup times without significant modification to their system and existing save processes?
A. Library-based tape encryption
B. Virtual Tape Library
C. VIO Server (VIOS)
D. Backup and Recovery Media Services Advanced Feature
正解:B
質問 3:
A customer wants to replace their single-partition POWER5 system with a POWER7 system that will run 2 IBM i partitions. What is needed in order to transfer the IBM Licensed Program Products?
A. The license key of the license program from the POWER5 system
B. A software maintenance contract for the POWER7 system
C. A proof of entitlement
D. The original POWER5 system invoice
正解:C
質問 4:
In which situation is the FC #EB34 IBM i 6.1.1 Native I/O feature required?
A. To implement a single-image system on a POWER7+ server running only IBM i 6.1
B. To allow a POWER7+ system to run external I/O
C. To enable a POWER7 system to host a Linux partition
D. To configure a POWER6+ or POWER7 system to run client I/O for an IBM i 6.1 partition
正解:A
質問 5:
A customer has an IBM i host partition with 3 IBM i client partitions. All client partitions only perform their full system backups using a shared LTO-5 tape drive.
Which of the following is a valid consideration in this environment?
A. Media and Storage Extensions is required on the client partitions.
B. Backups will be stacked on the tape.
C. In a Disaster Recovery scenario, recovery will be one partition at a time.
D. Sufficient disk on the host partition is required to buffer backups when two partitions are using the tape drive simultaneously.
正解:C
質問 6:
A P0WER6 customer plans to move to 6-core POWER7+ technology using an MES upgrade. What unique capability does this provide?
A. IBM i license transfer option
B. External SSD drawer support
C. No charge processor activation
D. Maintain the current serial number
正解:D
中前** -