Given a default installation of IBM Tivoli Storage Productivity Center V5.1 (TSPC) on a Windows server, what is the correct location for the TSPC configuration files?
A. C:\Program Files\TPC\config
B. C:\Program Files\IBM\TPC\install\config
C. C:\Program Files\IBM\TPC\config
D. C:\Program Files\IBM\config
正解:C
質問 2:
Which panel is used to view information about the performance monitor?
A. Topology
B. Configuration Utility
C. Job Management
D. Services
正解:C
質問 3:
An IBM Tivoli Storage Productivity Center V5.1 administrator is viewing a server service log file and wants to search for a string value. What action is taken to search the server service log file?
A. right-click the log file display and select Search for
B. enter the string value in the Search for box at the top of the log file display
C. on the top menu bar, click View > Search for
D. on the top menu bar, click Edit > Find on Page
正解:B
質問 4:
Where would a customer look in the IBM Tivoli Storage Productivity Center stand-alone GUI to verify probes and performance monitor failures?
A. under Job Management
B. under Disk Manager
C. under Discovery
D. under Services
正解:A
質問 5:
Data retention of missing resources within the IBM Tivoli Storage Productivity Center V5.1 database repository is handled by configuring the retention duration under the expanded GUI Navigation Tree location Administrative Services > Configuration > Removed Resource Retention. Which element can be configured to specify the number of days to keep information that has been removed from the system and can no longer be found?
A. Files
B. Tape
C. Pings
D. Network Router
正解:B
質問 6:
A storage administrator monitors two Tivoli applications -- IBM Tivoli Storage Productivity Center and IBM Tivoli NetCool/OMNIbus (OMNIbus). The administrator wants to be notified and the alert to be forwarded to OMNIbus when the file system has consumed 85% or more of the available storage space. Which two options should be set? (Choose two.)
A. Triggered Action, select SNMP Trap
B. Triggering Condition = File System Is Low on Absolute Free Space Set Value = 15% Set Value Units = Percent
C. Triggering Condition = File System Free Space Less Than Set Value = 15% Set Value Units = Percent
D. Triggered Action, select TEC/OMNIbus Event
E. Triggering Condition = File System Is Low on Relative Free Space Set Value = 15% Set Value Units = Percent
正解:C,D
質問 7:
What conditions must be met to start a Storage Optimizer job?
A. The device has been discovered, probed, and performance data collected.
B. The device has been probed and a scan started.
C. The device has been probed, scanned, and performance data collected.
D. The device has been discovered and probed.
正解:A
質問 8:
What is the recommended number of CIMOM's that can be installed on an IBM Tivoli Storage Productivity Center V5.1 server?
A. two
B. four
C. five
D. zero
正解:D



0 お客様のコメント