An NFS client is using nfs01_lif on homeport e0b on node1 for data traffic. After a head swap from node2, the administrator performs a takeover and notices that the client no longer has access to the data. What caused the client to lose access to the data?
A. There is no broadcast domain configured for NFS traffic.
B. The IPspace is configured for a CIFS workload.
C. The subnet is configured to fewer IP addresses than necessary.
D. The failover group is configured only with the e0b port from node1.
正解:D
解説: (Pass4Test メンバーにのみ表示されます)
質問 2:
A 4-node NetApp ONTAP cluster sent an AutoSupport message for a single power supply failure in the cluster. The alert shows a failure for both node-1 and node-4. Why are two different nodes affected by the failure?
A. There is a failure in cluster interconnect switch-1.
B. There is a failover of node-2 to node-1.
C. Both node-1 and node-4 are in the same chassis.
D. There is a failover of node-3 to node-4.
正解:C
解説: (Pass4Test メンバーにのみ表示されます)
質問 3:
At what stage is a write acknowledged to a client?
A. when the write has been flushed from NVRAM to RAM
B. when the write is present in the NVRAM on the local node and its HA partner
C. when the write is present in the local node RAM and NVRAM
D. when the write has been flushed to disk
正解:B
質問 4:
You have replaced the cluster backend switches on a 4-node NetApp ONTAP cluster with new switches. After the replacement, you realize that the system shows errors for the old switches that were removed:

You also notice that system switch ethernet showshows four switches, the two old switches and the two new switches.
What action will resolve the issue?
A. Delete the old switches from the database using the system switch ethernet delete command.
B. Perform a reboot of the affected node using the storage failover takeover command.
C. Reconnect the old switches and download a support bundle using the system switch ethernet log collect command.
D. Clear the health alert using the system health alert delete command.
正解:A
解説: (Pass4Test メンバーにのみ表示されます)
質問 5:
You have an air-gapped NetApp ONTAP based system that has recently had a node panic, and the node is back online. To assist in troubleshooting, the NetApp Support team has asked you to submit the core file for analysis. Which two methods do you use to access the core files from the ONTAP controllers in this environment? (Choose two.)
A. Use the system node autosupport invoke command.
B. Use the system node coredump external-device command.
C. Collect files from the SPI of the affected nodes.
D. Use the system node coredump upload command.
正解:B,C
解説: (Pass4Test メンバーにのみ表示されます)
質問 6:
A NetApp system displays repeated ECC memory errors on one DIMM, but the node remains online. What is the BEST support recommendation?
A. Replace the affected DIMM during a maintenance window
B. Reboot the cluster weekly
C. Ignore the issue until system failure occurs
D. Downgrade ONTAP immediately
正解:A
解説: (Pass4Test メンバーにのみ表示されます)
質問 7:
You are using wafliron on an aggregate named homedir on a production system. When is the data on homedir available?
A. after Phase 4 of wafliron is complete
B. when the administrator manually onlines the aggregate
C. after the mounting phase of wafliron is complete
D. when wafliron is started
正解:A
解説: (Pass4Test メンバーにのみ表示されます)
917 お客様のコメント





Ogawa -
NS0-094過去問から合格に必要な問題を厳選して分野別に収録しているから良いね