You have three Windows servers and one Linux server, each with dual-ported HBAs that are connected into a dual fabric.
In this scenario, what is the minimum number of zones that you need to create within each fabric switch?
A. 8
B. 4
C. 1
D. 2
正解:A
質問 2:
Exhibit:

A customer has an AFF A200 with a LUN residing in a volume by Node 4. The default Selection Mapping settings are effect. During a planned takeover cluster test, Node 3 performs a take over of Node 4.
Referring to the exhibit, what is the expected number of paths seen from the host?
A. 8
B. 4
C. 6
D. 2
正解:C
質問 3:
You want to create an additional SVM from the System Manager GUI to serve data only using block-based protocols. You know the SVM name, the aggregate containing the root volume, and the required protocols.
What other information is required to successfully create this SVM?
A. search domains
B. root volume security style
C. name servers
D. SVM Management LIF network details
正解:B
質問 4:
Automatic host-side space management with SCSI T10 thin-provisioned LUNs is achieved by which feature of ONTAP?
A. space allocation
B. fractional reserve
C. space reservation
D. volume auto-grow
正解:A
質問 5:
You want to provision an iSCSl LUN.
Which two steps are required to accomplish this task? (Choose two.)
A. Map the LUN to the igroup.
B. Add the initiator IP address to the igroup.
C. Add the initiator 1QN to that igroup.
D. Add the target WWPN to the igroup.
正解:A,C
質問 6:
A customer's NetApp infrastructure is reaching end-of-life (EOL), and they want to inventory their NetApp cluster. The customer wants to make sure that the proposed technical refresh satisfies their growing data demands.
Which two tools would you use to help with this recommendation? (Choose two.)
A. OneCollect
B. Upgrade Advisor
C. Config Advisor
D. Active IQ
正解:B,C
質問 7:
You have a 4-node cluster with a FAS8200 HA pair and an AFF A300 HA pair. You need to migrate a LUN from a FAS8200 node to an AFF A300 node for faster performance.
Which method will non-disruptively migrate the LUN to the AFF A300 while retaining snapshots of the LUN on the FAS8200?
A. You move the LUN.
B. You relocate the aggregate.
C. You move the volume.
D. You copy the LUN.
正解:D
質問 8:
An administrator who is using the Virtual Storage Console (VSC) creates a new FC datastore on an existing volume. While the datastore was provisioned, two hosts were in maintenance mode. When the maintenance was completed, the two hosts do not have access to the new datastore, but they have access to other datastores on the same volume.
In this scenario, what caused this result?
A. The VSC created a new igroup that contains only the hosts that were online during the datastore creation.
B. During host maintenance, the FC HBAs were replaced with different FC HBAs.
C. After creation using the VSC, the administrator needs to create a LUN mapping.
D. The VSC cannot create datastores while hosts are in maintenance mode.
正解:A
質問 9:
Which formula is appropriate for calculating target port Queue Depth?
A. The sum of the Queue Depth setting for all hosts using a physical port
B. The number of physical ports * 2048
C. The number of LIFs using the physical port * Maximum Host HBA Queue Depth setting
D. The number of LIFs using a physical port * 256
正解:C
Hara -
問題集の質問と解答を読むことを繰り返し、きちんと暗記して、NS0-509合格できました。