Your customer is close to approving a sale of 35 server systems which require maximum memory configurations. While looking at the Bill of Materials you are asked what (if any) are the benefits of using LR-DIMM over RDIMM. And if there are none to go with RDIMMS. How would you answer him?
A. LR-DIMM's have a dedicated memory controller, which offloads CPU cycles
B. Mirroring/Sparing memory mode can be set up usingLR-DIMMs
C. LR-RDIMM's support ECC
D. LR-DIMM's speed is higher
E. More memory can be installed, since LR-DIMM supports rank multiplication
正解:E
質問 2:
Your customer is looking for a Server System which will support two high-end GPGPU cards. As the Intel@ Server Specialistwhich of the following server systems would you recommend? (Select ALL that apply).
A. Intel@ Server System P4304CR2LFKN
B. Intel@ Server System H2216XXKR2 and HNS2600KP
C. Intel@ Server System P4308RPLSHDR
D. Intel@ Server System P4308RPLSHDR
E. Intel@Server Chassis P4304XXMUXX and board S2600CW2
正解:A,E
質問 3:
Your customer has a dual socket server board; and they have complained to you that their customer is constantly getting PCIe errors. At yourrequest they send you the System Event log. On investigation of the SEL by you, you discover some events that look like the following: TimeStamp:03/05/2014 12:18:41 SensorName:PCIe Cor Sensor. Bus:0, device:3, function:2
Which one of the following represents the correct order in which troubleshooting should occur?
A. A, D, C
B. A, F, E
C. If the error happens regularly, try to cross-test PCIe devices to see if the error follows the card or stays with the slot.
D. Rerun the FRU/SDR to force the system to detect the correct PCIe generation for this device.
E. List through the error codes from the User guide to find the translation table for the SEL in order to identify the failing device and link speed.
F. If error happens very rarely, disable AER reporting in BIOS
G. A, B, E
H. Check SEL troubleshooting guide in order to understand PCIe bus, device, function of the card that generates the error. Then check TPS to identify the slot to find the suspect component.
I. Force slower PCIe link speeds in the BIOS setup utility.
J. B, C, F
正解:F
質問 4:
Your customer calls you to say that since the BMC Watchdog timer was enabled, the system reboots continuously. What would your advice be from the list below? (Select ALL that apply).
A. Do a CMOS clear
B. Install Intel@ Active System console
C. Disable automatic reboot in Windows
D. Install the IPMI driver and create a script for the Watchdog refresh
E. Install the IPMI driver
正解:B,D
質問 5:
Intel@ Deployment Assistant is designed to simplify the setup and configuration of Intel@ Server Products. Which of the following features are included with Intel@ Deployment Assistant? (Select ALL that apply).
A. Unattended operating system installation
B. Cross-compatibility with a wide range of Intel architecture based server products
C. Memory and storage sizing guidance by application type
D. Single interface for configuring system BIOS, management, and RAID settings
E. Server cloning
正解:D,E
質問 6:
Your customer is in the market to upgrade their HPC infrastructure. Thereforeintegrated Infiniband is seen to be a base essential and must be down on the board. Please advise your customer as to which systems could answer their needs from the list below:
A. Intel @ Compute Module HNS2600KP
B. Intel @ Compute Module HNS2600TP
C. Intel @ Server System R1208WTTGS
D. Intel @ Compute Module HNS2600TPF
E. Intel @ Server System R2208WTTYC1
正解:D
質問 7:
What speeds do the integrated Ethernet controllers (LOM) support, in the current generation - Grantley (S2600 series boards for Intel Xeon E5v3 series CPUs)? (Select ALL that apply).
A. 10 Gb/s
B. 15 Gb/s
C. 1 Gb/s
D. 40 Gb/s
E. 5 Gb/s
F. 2.5 Gb/s
正解:A,C
質問 8:
From the following list, when might a customer find Intel@ Active System Console helpful?
A. To ensure all drivers are up to date
B. To updatethe BIOS, BMC, and FRU SDR for the server
C. To analyse the operating system event logs
D. To identify the cause of a blinking status LED
正解:D
質問 9:
A customer asks which technologies are supported in Intel@ Server Chipsets. How should an Intel@ Server Specialist respond from the following options?
A. Intel@Virtualisation Technology for Routing
B. Intel@ Virtualisation Technology for Directed I/O
C. Intel@ Virtualisation Technology for Connectivity
D. Virtual Machine Device Queues
正解:B
新生** -
きっちりとまとまっていてわかりやすかったです。効率よくISS-003学習できそうです。