A technician needs to set a server to always attempt PXE boot before booting to the hard drive.
What two items does the technician need to set to achieve this? (Choose two.)
A. Remove all boot options except network card
B. Change the Boot Sequence so the network card is first
C. Select PXE Boot from F11 Boot Manager
D. Set the Legacy Boot Protocol for the network card to PXE
正解:A,B
質問 2:
Refer to the exhibit.
A technician it installing an OS to a server. The OS array is 2.8TBs. The OS install is unable to start.
What should the technician do to install the OS?
A. Use LC to install the OS
B. Switch the Hard Drive boot sequence so that C: is first
C. Switch the boot settings to UEFI
D. Use USB to load Storage Drivers
正解:B
質問 3:
A PowerEdge server is running a hypervisor. The server must be configured to enable multiple virtual machines to share the PCIs hardware resources of a supported NIC.
Which System BIOS setting must be enabled to provide this functionality?
A. Single Root I/O Virtualization
B. Memory Mapped I/O above 4 GB
C. Virtualization Technology
D. DirectPath I/O
正解:D
質問 4:
A systemboard was replaced. After the replacement, the system will NOT boot into Windows and gives the error 'No boot device found'. Virtual disks are seen and optimal.
What action should a technician take to resolve this issue?
A. Change the boot settings from BIOS to UEFI
B. Insert the Windows media to fix the MBR
C. Reseat the RAID chain
D. Make sure that the iDRAC license was imported
正解:B
質問 5:
A technician needs to deploy a server into production. The technician needs to verify that the firmware levels match corporate policy before putting the server on the business network.
Which two methods should the technician use to verify the firmware version of iDRAC and BIOS? (Choose two.)
A. Log into the iDRAC web interface to view Server Information
B. Use the OMSA DVD that came with the server to view Current Drivers and Firmware
C. SSH into the iDRAC and run the command racadm systemconfig to view current firmware
D. Use the Lifecycle Controller and navigate to Firmware Update to view current versions
E. Scroll through the menus on the LCD panel to view the BIOS and iDRAC firmware levels
正解:C,E
質問 6:
A technician wants to move memory from a few older system into a newer system.
What is the most efficient method for the technician to accomplish this task?
A. Use iDRAC to view the memory details of the older systems. Power down the servers to move matching memory to the new server
B. Back up the server profile on the older server, move the matching memory, and import the server profile to the new server
C. Power down all of the older servers to physically check the memory. Move any matching memory to the new server.
D. Power down any of the older servers to move any memory to the new server, update BIOS to allow mis-matched memory.
正解:D
北村** -