A consultant is asked to help evaluate an environment for deployment into a new software-defined data center (SDDC) in VMware Cloud on AWS. The consultant is provided with a comma-separated value (CSV) file containing a list of workloads exported from VMware vCenter detailing only virtual machine configuration data, including vCPU, vRAM, and utilized storage.
How should the consultant use the VMC on AWS Sizer?
A. Use the Advanced Sizer. Import the CSV file from VMware vCenter Server and let the VMware Cloud on AWS Sizer set the values for configured resources.
B. Use the Advanced Sizer. Create workload profiles for the different workload types and set the values for configured resources manually.
C. Use the Quick Sizer. Manually enter the number of virtual machines and total resources for configured resources.
D. Use the Advanced Sizer. Import the CSV file from VMware vCenter Server and let the VMware Cloud on AWS Sizer set the values for configured resources.
正解:C
質問 2:
Standard security practice for a company requires that all administrator-level user accounts have their passwords changed every 60 days. The [email protected] account password is changed by an administrator through the VMware vSphere Cliento adhere to the security policy. When the administrator attempts to log into the VMware Cloud on AWS vCenter Server through the VMware vSphere Client a few days later as [email protected] using the account credentials copied from the VMware Cloud console, the administrator's access is denied.
What is the likely cause of this issue?
A. When the password for [email protected] is updated from the VMware vSphere Client, the updated password is not reflected in the VMware Cloud console.
B. The [email protected] password change confirmation email has not been approved by an Organization Owner.
C. The [email protected] account password should only be changed through the appliance management interface of the VMware vCenter Server.
D. The [email protected] account password should not be changed through the VMware vSphere Client. In order to prevent unauthorized access to VMware Cloud on AWS by non-authorized individuals, VMware will lock the account out.
正解:A
質問 3:
When configuring Hybrid Linked Mode from the vCenter Cloud Gateway appliance, which groups are mapped from a customer's on-premises environment to the cloud?
A. LDAP Groups
B. Active Directory Groups
C. vSphere Groups
D. Local Groups
正解:B
質問 4:
An environment is running a cluster with six i3.metal hosts in the VMware Cloud on AWS software-defined data center (SDDC).
If one host fails, what happens after a new host is automatically added to the cluster?
A. A notification is received from VMware Support to start the VMware vSAN rebuild Performance might be degraded during rebuild.
B. The VMware vSAN rebuild starts in the background. Performance might be degraded during rebuild and the failures to tolerate (hi I) is lowered to 0.
C. The VMware vSAN rebuild starts in the background. Performance might be degraded during rebuild and the failures to tolerate (hi I) is lowered to 1.
D. The SDDC and NVMe drives backing VMware vSAN capacity are unmounted from the failed host and attached to the new host. There is no VMware vSAN rebuild required.
正解:C
解説: (Pass4Test メンバーにのみ表示されます)
質問 5:
An administrator is deploying a VMware Cloud on AWS software-defined data center (SDDC) in an AWS region and needs to plan for mission-critical application availability across availability zones.
Which AWS Virtual Private Cloud (VPC) configuration needs to be in place in order to accomplish this?
A. Two AWS VPCs with two subnets, two per availability zone
B. One AWS VPC with two subnets, one per availability zone
C. One AWS VPC with four subnets, one per availability zone
D. Four AWS VPCs with two subnets, two per availability zone
正解:A
質問 6:
Due to a recent acquisition, an architect is being asked to identify and design a cloud-based solution that will assist in merging several data centers together without incurring undue operational overhead while adhering to a very strict project timeline. The proposed solution must have the capability to be rapidly recovered in the event of a cloud provider outage. After careful consideration, the architect determines that VMware Cloud on AWS would be an appropriate solution, requiring a total of nine hosts for capacity.
Which additional configuration options would satisfy the requirements of this project?
A. Deploy a VMware Cloud on AWS software-defined data center (SDDC) with a single stand-alone cluster.
Deploy a second stand-alone cluster into the SDDC in a separate region.
Configure VMware Cloud Disaster Recovery to replicate and protect workloads to the second cluster.
B. Deploy a VMware Cloud on AWS software-defined data center (SDDC) with a single stretched cluster across two separate regions.
Configure the cluster to ensure that all virtual machines can be restarted in the second region with a near zero recovery point objective (RPO) in the event of any environment or system failures.
C. Deploy a VMware Cloud on AWS software-defined data center (SDDC) with a single stand-alone cluster.
Deploy a second SDDC with a stand-alone cluster into a different AWS region. Configure VMware Cloud Disaster Recovery to replicate and protect workloads to the second cluster.
D. Deploy a VMware Cloud on AWS software-defined data center (SDDC) with a single stretched cluster across two separate availability zones.
Configure the cluster to ensure that all virtual machines can be restarted in the second availability zone with a near zero recovery point objective (RPO) in the event of any environment or system failures.
正解:D
質問 7:
The Tier-O (TO) router will send northbound packets through which device?
A. The AWS Elastic Network Adapter (ENA) of the VMware ESXi host that the active TO Edge virtual machine is currently running on.
B. The AWS Elastic Network Adapter (ENA) of the VMware ESXi host where the packet is originating from.
C. The AWS Elastic Network Adapter (ENA) of the VMware ESXI host that the passive TO Edge virtual machine is currently running on.
D. The AWS Elastic Network Adapter (ENA) of the VMware ESXi host that is currently the least utilized.
正解:C
905 お客様のコメント





Takahisa -
またお世話になりました。5V0-33.23に合格しましたのでここで報告と感謝差し上げます。的中率高めでした。ありがとうございました。