A customer has configured two LAGs on their Hitachi NAS Platform 3090 cluster. EVS A uses ag1 and EVS B uses ag2.
What will cause EVS A to failover?
A. All the GbE ports go offline from ag1.
B. The SMU quorum service is stopped,
C. All the EVSB file systems go offline.
D. The cluster interconnect goes offline.
正解:A
質問 2:
You are designing a solution to replace a customer's existing NetApp FAS3140. The customer uses Snapshot and SnapMirrorto provide local snapshots and DR protection. They perform a daily snapshot which is retained for 30 days and they execute SnapMirror on a 15 minute interval. In the event of a failover to the DR site, all the locally executed snapshots are available for use on the DR system.
How should you configure snapshot rules with replication to provide equivalent capabilities?
A. on the source and target systems using a single object replication policy
B. on the source system that is referenced by the object replication policy
C. on the target system only referenced by the object replication policy
D. on the source and target systems using two different object replication policies, one of which references both snapshot rules
正解:D
質問 3:
A customer requires a VSP asynchronous replication solution for their Hitachi NAS Platform 4000. They have two data centers that are over 500 km apart. They are concerned with intermittent network connectivity problems and would like to leverage disk-based journaling.
Which block-based replication should be used?
A. Hitachi TrueCopy
B. Hitachi TrueCopy Extended Distance
C. Hitachi Universal Replicator
D. Hitachi Shadowlmage
正解:C
質問 4:
A customer recently purchased a Hitachi NAS Platform 4000 and a Hitachi HUS 130 for back-end storage. They are concerned about back-end performance.
What are two best practices? (Choose two.)
A. Do notmixSAS 10K and SAS 7.2K in the same untiered storage pool.
B. Do not share storage ports with another other host.
C. Do not exceed 8 SAS 7.2K LUNS per FC port.
D. Do not use FC Loop mode.
正解:A,B
質問 5:
An enterprise customer has a diverse Active Directory environment consisting of multiple untrusted departmental Windows domains.
Which EVS security configuration will achieve this business requirement?
A. Use IPSec for all EVS to create secure client connections.
B. Use an independent EVS security context for each EVS.
C. Use SSL certificates to encrypt client communications.
D. Use the global EVS security context for all EVS.
正解:B
質問 6:
You have prepared a solution upgrade proposal for an existing Hitachi NAS Platform customer who is planning to purchase additional nodes. While presenting to your customer, they ask about mixing models within a cluster.
Which statement is correct?
A. Mixing 3000 models within a cluster is supported.
B. A cluster can be made of different models.
C. All models can be clustered with each other.
D. A cluster must be made of the same models.
正解:D
Miyasaka -
HH0-350問題集のおかげで、無事にHH0-350試験に合格しました。ほんとにありがとうございました。