A customer has several client IBM i partitions hosted by a single VIO Server. The system has one Shared Ethernet Adapter. The administrator has noticed that network performance is significantly degrading as traffic increases. The system workload has not changed.
Which statement describes a possible cause of this problem?
A. Simultaneous Multi-Threading is enabled but single-threaded workloads are running.
B. There are insufficient vLANs configured to support the network traffic.
C. TheVIOServer is also hosting vSCSl, and the threading option is disabled on the Shared Ethernet Adapter
D. Virtual Ethernet is being used instead of physical adapters.
正解:C
質問 2:
Disk from a fibre-attached V7000 disk subsystem will be used for an IBM i partition. What type of adapter is required in the IBM i partition?
A. Virtual SCSI adapter
B. SAS disk adapter
C. Fibre Channel adapter
D. Virtual SAS adapter
正解:A
質問 3:
What IBM software is the minimum required to share an IBM tape library connected to multiple IBM i partitions using NPIV?
A. Tivoli Storage Manager
B. Backup and Recovery Media Services
C. Media and Storage Extensions
D. VIO Server
正解:D
質問 4:
An operator shut down an operating IBM i partition from the HMC. What is the result of this action?
A. RAID integrity may be compromised.
B. The next IPL of the partition will be an abnormal IPL.
C. Objects in disk IOA write cache will be lost.
D. The next IPL will need to be manual and will require a Reclaim Storage to complete.
正解:B
質問 5:
What type of server and client adapters must be configured on the HMC to support virtualized disk presented from a V7000 SAN to an IBM i client partition?
A. One vSCSI server adapter One vSCSI client adapter
B. One SCSI server adapter One ISCSI client adapter
C. One Fibre Channel server adapter One Fibre Channel client adapter
D. One NPIV server adapter One NPIV client adapter
正解:A
質問 6:
What is the correct method to install a firmware update on a single-image system?
A. Download the firmware and burn it to a CD, then perform a D-side manual IPL.
B. Install the appropriate firmware PTF package to the IBM i partition and IPL the partition.
C. Load the firmware CD to the optical drive and perform a LODRUN operation.
D. From the DSPEMWSTS screen, use the function to "Update firmware from service machine."
正解:B
質問 7:
A POWER7 system has 6 IBM i partitions sharing a single shared processor pool. The system has 3 IBM i operating system licenses. Without exceeding the licenses available, what is the largest allowable value for the "Maximum processing units" setting in the shared processor pool?
A. 1
B. 3
C. 6
D. 2
正解:B
質問 8:
A client partition has disk storage provided by two different hosting partitions. What method of disk protection on the client partition will help ensure that the client partition remains running in the event one of the hosting partitions becomes unavailable?
A. ASP-levelmirroring
B. RAID-5 with hot spare
C. PAID-6
D. Adapter-level mirroring
正解:D
質問 9:
A system administrator has configured 3 partitions, each using 1 of 3 shared processor pools. All are active and working as designed.
One of the partitions using one of the shared processor pools will be shut down and the resources allocated to the other 2 pools.
Which is the correct sequence of actions to accomplish the goal?
A. Change the minimum processor for the partition to zero.
Shut down the partition by deactivating it from the HMC.
Delete the shared-processor pool.
B. Shut down the partition that is using the shared processor pool.
Change the maximum processing units to zero.
Assign the processor capacityto another pool.
C. Merge the shared-processor pool to be removed into one of the other pools.
Shut down the partition by deactivating it from the HMC.
Plush the memory cache by deactivating the shared-processor pool.
Delete the shared-processor pool.
D. Create a new shared-processor pool.
Merge all three shared-pools into the new pool using Live Partition Mobility
Shut down and remove the partition definition.
正解:B
芳贺** -
C4040-121知っておくべき内容が簡潔に説明されているので
効率的に知識を得ることができます。