What are two basic requirements for establishing the UCM/ClearQuest integration? (Choose two.)
A. It is possible for a Rational ClearQuest user database to contain some records that are linked to activities and some records that are not linked.
B. After you establish the UCM/ClearQuest integration between a UCM project and a ClearQuest user database, you can change the association to another ClearQuest database as long as the database has the same schema version.
C. The schema version of the ClearQuest user database must have all the necessary packages applied in order to become a candidate for UCM/ClearQuestintegration.
D. One UCM PVOB can only associate with one ClearQuest database in the UCM/ClearQuest integration.
正解:A,C
質問 2:
The ClearCase Report Builder can be used to extract information from ClearCase. Which two statements are trueabout ClearCase Reports? (Choose two.)
A. There is no way to customize the directory organization displayed in the tree pane.
B. As with the Report Builder, it is possible to customize the Report Viewer by adding,
changing, or removing informationsuch as a column
heading name.
C. As with the Report Builder, there is no way to customize the commands on the pop-up
menu.
D. It is possible to customize the name of the folders in the tree pane and the report
parameters.
正解:B,D
質問 3:
Which command is used to create the AdminVOB hierarchy?
A. cleartool mkadminvob
B. register
C. cleartool mkvob
D. cleartool mkhlink
E. cleartool ln
正解:D
質問 4:
Which two statements are true? (Choose two.)
A. Once a branch type exists, you can create instances of that branch type.
B. If a branch type exists in one VOB, you cannot create that branch type in another VOB.
C. The preferred method of instantiating branch types is using the kbranch clause in view config spec.The preferred method of instantiating branch types is using the ?kbranch clause in view config spec.
D. A branch type should be ONLY in lower case.
正解:A,C
質問 5:
Your IT decides to use NAS or SAN with a VOB server, but the filer device is often busy. Which two actions should you take to address this issue? (Choose two.)
A. keep the VOB database files on the VOB server
B. move to a Windows VOB server that utilizes the efficient SMB protocol
C. keepthe VOB database files on the filer and leave the pools on the VOB server
D. move the VOB database pools to the filer device
正解:B,C
質問 6:
What must you do when moving a VOB?
A. delete the old VOB storage directory to free the storage it consumes
B. make sure that access control is preserved while copying the VOB directories
C. ask users to unmount the VOB before you begin the move
D. reduce the VOB storage directory size by scrubbing the VOB poolsreduce the VOB storage directory size by scrubbing the VOB? pools
正解:B
質問 7:
Which two statements are true about default config spec rules? (Choose two.)
A. The line "element * /main/LATEST should always be the second config spec rule to select all checked-in versions at main branch after the checked-out versions.
B. The line "element * CHECKEDOUT" should be always the first config specrule to select all checked-out versions available in your view before the checked-in versions.
C. If another developer checks in a new element's version at the main branch in the same VOB, the new and latest version will only appear after the ClearCase update command is executed.
D. The load rule should be the third rule to allow any view to load the element's versions.
正解:A,B
質問 8:
What is an accurate description of a standard VOB backup? (Assume that the backup utility is able to capture files that are "open for write.")
A. shut down ClearCase; copy the VOB physical storagedirectory to another disk location; restart ClearCase
B. lock the VOB with the -nusers vobadm option; back up the entire VOB storage directory; unlock the VOB
C. lock the VOB; back up the entire VOB storage directory; unlock the VOB
D. lock the VOB; unregister the VOB; back up the entire VOB storage directory; unlock the VOB; re-register the VOB
正解:C